BBC Micro power supply with blown Rifa capacitors before servicing

The Rifa X2 suppression capacitors are the common problem in BBC Micro power supplies, and this one had gone bang and let loose its magic blue smoke. So I repaired it and serviced the whole PSU using the advanced servicing kit from Retro Clinic, step by step so you can do it too. This video was sponsored by PCBWay.

As well as replacing the blown Rifa X2 caps, the advanced kit replaces the startup, main smoothing and low voltage capacitors, and gives the PSU better smoothing on the -5V line. It’s the one I recommend, but if you just want to change the blown capacitors there’s a smaller kit for that too. Buy a servicing kit at retroclinic.com.

Which BBC Micro PSU does the kit fit?

The instructions warn that this kit is only for the Astec and BSR variants of the BBC power supply. Mine is the BSR version, so I was good to go. The kit is a hefty bag of parts with very detailed instructions: genuine Rifa capacitors, high quality Panasonic electrolytics and a few flashy red cable ties.

Advertisement

Getting the board out of the case

First the metal surround comes off. Then, with the supply turned over, remove the two earth bonding nuts, star washers and screws (one at each end). Keep the nuts and washers with their bolts. I dropped one star washer straight away and eventually found it stuck to the earth cable. Three screws with flat washers hold the board in the case, and some lunatic had filled one with threadlock (a scalpel sorted it out).

Next, cut the cable tie on the input wiring and pull off the mains switch spade connectors. Lesson learned here: take the switch out of the case first and then disconnect it, which gives you far more room. The switch comes out by flattening the case grips while you squeeze it through; note that its metal terminals are at the bottom. The auxiliary power connector comes out the same way, then the board lifts out of the case (with the obligatory retro repair dead bug inside).

Removing the old capacitors

The capacitors to come out are the two X2 suppression caps at C1 and C2, the startup cap at C9, the big pair at C6 and C8, and C16 to C21 on the low voltage smoothing side. I used my desoldering station; if you want a decent manual tool, get an SS-02 solder sucker, which I use daily. There’s no need to note the old values because the instructions are comprehensive, and some replacements are deliberately higher values for better performance.

C1 was still intact but showing stress fracture lines. C2 had clearly gone to capacitor Valhalla, falling to bits as I removed it, with a massive crack. You can see exactly where it overheated and squirted all over the face of the board.

Soldering iron on the underside of the BBC Micro power supply board, desoldering the failed Rifa X2 capacitor at C2
Desoldering the failed Rifa X2 capacitor at C2

C6 and C8 were hot glued at the factory to stop vibration cracking the solder joints. Remember that electrolytics usually mark the negative leg on the case, while this board marks the positive hole.

BBC Micro power supply board showing residue where the X2 capacitor overheated and burst
Where the X2 cap overheated and sprayed the board

Cleaning the board

A clean board is the most important factor in successful soldering. I used 99.9% isopropyl alcohol on the vacated pads to remove grease and contaminants that stop solder taking, then gave the top side a second rinse and dried it with clean cotton swabs. Some of the staining won’t come off, but the areas you’re working on are what matter.

Fitting the new capacitors

  • C1: 10nF X2 (the two X2 caps look similar but are not the same, so check)
  • C2: 100nF X2. X2 caps aren’t polarised, so either way round is fine.
  • C9 (startup): 220µF 35V
  • C6 and C8: 100µF 250V. Get these the right way round or they’ll explode very quickly.
  • C18 and C21: 220µF 35V (originally 100µF; the change improves smoothing on the -5V line)
  • C16, C19 and C20: 1000µF 25V
  • C17: 2200µF 16V

For polarised caps, the longer leg is positive and goes in the hole marked positive. I spread the legs to hold each part in place, then soldered with extra liquid flux (I like the Topnik no-clean type, whose residues won’t corrode the board over time; make sure you have good ventilation). Heat the pad and the leg together so the solder flows evenly into a slightly convex, volcano-shaped joint, and snip the leads without cutting into the joint. Triple check polarity: it’s very easy to make a mistake if you lose concentration.

Soldering new Rifa X2 suppression capacitors into a BBC Micro power supply board with liquid flux
Soldering in the new X2 suppression caps

I used leaded solder. This PSU would have been built with leaded solder in the 80s, and putting unleaded on top of leaded leads to fragile joints.

Check the transformers and choke

Some components are coated in what looks like brown toffee: that’s normal, and it’s there to suppress vibration. Because they vibrate, check the solder joints on the input choke and the two transformers for concentric rings or hairline cracks, and wiggle each component to see if the legs move in the joints. Mine were all fine, but reflow yours if you’re not sure. Also check you’ve snipped every lead and haven’t left any offcuts on the board or in the case.

Reassembly

It’s mostly the reverse of disassembly. The auxiliary connector should clip in with a firm snap. Fix the board back in with its washers (I put the threadlock screw back in the wrong place, just to annoy people). Refit the switch with its four contacts towards the bottom, and this time connect the board wires to it before pushing it into the case, paying attention to live and neutral. Then feed the blue and brown mains wires through and fit them on the same side as the other live and neutral wires.

For the earth bonding, the star washer goes on the case side, then the earth lugs, then the nut: start it with your fingers, then a screwdriver, then grips or a spanner. Tidy the wiring with cable ties, keeping the low voltage side clear of the heatsink, and check the BBC’s power feed cables are untangled and intact.

Fully serviced BBC Micro power supply reassembled in its metal case with new capacitors and tidy cable ties
The fully serviced BBC Micro PSU back in its case

The result

A fully serviced BBC Micro power supply with new suppression, startup and smoothing capacitors and improved -5V smoothing. Thanks to Retro Clinic for making such high quality kits.

Tools I used (affiliate links): a desoldering station like mine and a temperature controlled soldering station.

Related

More BBC Micro on the site: a BBC B with an MMC interface arrives. If you’re checking those transformer joints, my guide to identifying and repairing dry, cold or cracked solder joints will help.